Illustrated title card for the guide: 12V DC Fuse Blocks: RIGrunner vs PowerHub vs Blue Sea

12V DC Fuse Blocks: RIGrunner vs PowerHub vs Blue Sea

Compare the RIGrunner 4005, Powerwerx PowerHub PD-9F and Blue Sea 5025 by connector, fused outlet count, current limits and included fuses.

For a 12V setup with up to five Powerpole loads, choose the RIGrunner 4005 if you want blown-fuse indicators. For up to eight Powerpole loads, choose the Powerwerx PowerHub PD-9F. For six wired branches with screw terminals and a shared negative return bus, choose the Blue Sea ST Blade 5025. RIGrunner comparison chart, PowerHub PD-9F specifications, ST Blade 5025 specifications

Connections, current limits and included fuses

ModelFused branches and connectionsPublished current ratingsBlade fuses
West Mountain Radio RIGrunner 40055 top-mounted Anderson Powerpole outlets40 A maximum total and 40 A maximum per fused outletATC/ATO fuses installed
Powerwerx PowerHub PD-9F8 Anderson Powerpole outputs plus 1 input40 A continuous for the blockATO/ATC fuses included. The input comes with a 40 A fuse. Outputs come with three 25 A, two 10 A, two 5 A and one 1 A fuse.
Blue Sea ST Blade 50256 screw-terminal circuits for ring or snap-fork terminals, with positive and negative bus studs100 A maximum per block and 30 A maximum per circuitATO/ATC fast-acting fuses sold separately

The RIGrunner 4005 also has a listed 37 A fuse-limited ICAS rating. Powerwerx lists the PD-9F as compatible with 15 A, 30 A and 45 A Anderson Powerpole connectors. RIGrunner 4005 specifications, PowerHub PD-9F specifications

Check your load before you buy

Worked examples

Six Powerpole devices at 3 A each. The combined draw is 18 A. The PD-9F has enough outputs and passes the total-current check. The 4005 has five outlets. PowerHub PD-9F specifications, RIGrunner 4005 specifications

Three wired branches at 15 A each. The combined draw is 45 A, above the RIGrunner 4005’s 40 A total rating and the PowerHub PD-9F’s 40 A continuous rating. The Blue Sea 5025’s 30 A per-circuit and 100 A block ratings are above the example’s branch and combined loads, respectively. RIGrunner 4005 specifications, PowerHub PD-9F specifications, ST Blade 5025 specifications

Evidence and limits. The manufacturer listings for the RIGrunner 4005, PowerHub PD-9F and ST Blade 5025 and Blue Sea’s wire guide were checked on November 26, 2026. No hardware tests were performed. The worked loads are hypothetical.

Browse DC Distribution Guide articles

Related

Network-Managed Voltage-Monitored 12V DC Distribution Panels

Compare the Altronix LINQ8PD and RIGrunner 4005i for remote voltage readings, individual output control, and 12V DC load limits.

5.5×2.1 vs 5.5×2.5 DC Barrel Connectors and Powerpole

Compare 5.5×2.1 mm and 5.5×2.5 mm DC barrel connectors, check Powerpole housing orientation and wire sizes, and match polarity for an adapter.

12 V DC Equipment to Replace Homelab Wall Warts

Compare 12 V DC desktop supply and barrel plug requirements for homelab gear, and see the Blue Sea Systems 5025 distribution block’s published limits.