Choose the Altronix LINQ8PD for a retrofit that needs voltage readings at each output, provided its 3 A fused outputs fit your loads. Choose the RIGrunner 4005i if you need Powerpole outlets, want to see the shared input voltage, and can wait for a restock. Both let you switch outputs remotely. Altronix LINQ8PD, RIGrunner 4005i
Compare 12V DC distribution options
| Best fit | 12V supply compatibility | Outputs and current | Remote monitoring and control |
|---|---|---|---|
| Retrofit with voltage readings per output | LINQ8PD works with one or two compatible supervised DC power supplies or chargers. Each input is rated 12.5 A at 12 V DC. | Eight fused outputs rated 3 A each. | Supply and individual output voltage and load readings, with remote output control. Altronix LINQ8PD |
| Powerpole outlets | RIGrunner 4005i is designed for 12 V DC distribution. | Five independently switched outlets, with a 40 A total continuous rating. | Remote input-voltage and outlet-current readings, with individual on/off control. RIGrunner 4005i |
West Mountain Radio lists the 12V RIGrunner 4005i on backorder without a restock date. RIGrunner 4005i
Choose where to measure voltage
For a reading at the shared DC feed, the RIGrunner 4005i reports input voltage. For a separate reading at every branch, the LINQ8PD reports voltage at each output and lets you set high and low voltage limits per output. RIGrunner 4005i, Altronix LINQ8PD
Check voltage and current against your loads
- Check the feed. Compare its lowest and highest operating voltage with the panel’s DC input specification. Use the input voltage range under Specifications for the 12V RIGrunner 4005i. RIGrunner 4005i
- Assign each load an output. Count the branches and compare each load’s current with the rating for that output. The LINQ8PD has eight fused outputs rated 3 A each. Altronix LINQ8PD
- Add the loads that will run together. Compare their combined current with the panel or input rating and the available supply current. Suppose all eight LINQ8PD outputs draw 3 A each from a single 12 V DC input. Each load fits its output rating, but eight times 3 A exceeds that input’s 12.5 A rating. Altronix LINQ8PD
Check the management features
The LINQ8PD lists configurable high and low voltage limits per output, email notifications and an event log. The RIGrunner 4005i lists email alarms for high or low input voltage. Altronix LINQ8PD, RIGrunner 4005i
Evidence and limits. The linked manufacturer specifications for the LINQ8PD and RIGrunner 4005i were checked on November 27, 2026. Hardware and management functions were not tested.